Computer Operated Switch(COS)

Home Forums Knowledge Base Hardware Legacy Hardware Computer Operated Switch(COS)

  • This topic has 0 replies, 1 voice, and was last updated 19 years ago by Rob.
Viewing 1 post (of 1 total)
  • Author
    Posts
  • #1440
    Rob
    Member

    Computer Operated Switch(COS)
    by Black Box

    Last edited: December 15, 2003 08:07 AM
    Cabling

            CPU(DB25F) to COS(DB25M)
           


       


                  2    —  2  TXD
                  5    —  5  CTS
                  6    —  6  DSR
                  7    —  7  GND
                  20    —  20  DTR

            COS(DB25F) to WD8340(RJ45M)
           


       


                  2    —  4  TXD
                  6    —  5  RTS
                  7    —  7  GND
    Switches

            S1 – 7 Closed, Others Open for 9600 baud

            S2 – 3 Closed, Others Open for 04Hex Arming Code

            S3 – 4 Closed, Others Open for Word Format

            S4 – 4 Closed, Others Open to disable timeout

            Master Port Switches
           


            S5 – 2,3 Closed; 1,4 Open
            S6 – 1,4,5,7 Closed; 2,3,6,8 Open

            Output Port Switches(S7 through S23)
           


            S7(etc) – 2 Closed, Others Open  {8 Position Switches}
            S8(etc) – 1,4 Closed; 2,3, Open  {4 Position Switches}
    Template Escape Sequences

            Output Port 0 – 4,48
            Output Port 1 – 4,49
            Output Port 2 – 4,50
            Output Port 3 – 4,51
            Output Port 4 – 4,52
            Output Port 5 – 4,53
            Output Port 6 – 4,54
            Output Port 7 – 4,55