Toledo 8213 Scale and Interface
Last edited: December 15, 2003 08:18 AM
[color=red:vaijvyff][u:vaijvyff][b:vaijvyff]
Download Scale Interface[/b:vaijvyff][/u:vaijvyff][/color:vaijvyff]
Cable
CPU Scale
DB25
DB9
Female Male
2 — Transmit — 3
3 — Receive — 2
4 —
| Loopback
5 —
7 — Ground — 1
Switches
Leave at default settings(all OFF)
Levelling
Lift off top platter and adjust legs until bubble is centered within circle.
Calibration
Software Interface
Touchnet shells to SCALE.EXE which transmits a request out COM2 and waits up to five seconds for a valid response. The status is returned through Branch and must be zero or an error has occured. The scale groups all errors into a single byte added so many error numbers are possible but the common ones are listed below. If the status is zero then dollar 3 will contain the weight in hundredths of a pound.
Status Cause
0 Good transmission
1 Scale in motion
2 Weight greater than 30 lbs
3 Invalid response from scale
4 Weight less than zero
9 No response from scale