Toledo 8213 Scale and Interface

Home Forums Knowledge Base Hardware Legacy Hardware Toledo 8213 Scale and Interface

  • This topic has 0 replies, 1 voice, and was last updated 19 years ago by Rob.
Viewing 1 post (of 1 total)
  • Author
    Posts
  • #1473
    Rob
    Member

    Toledo 8213 Scale and Interface

    Last edited: December 15, 2003 08:18 AM
    [color=red:vaijvyff][u:vaijvyff][b:vaijvyff]
    Download Scale Interface[/b:vaijvyff][/u:vaijvyff][/color:vaijvyff]

    Cable

    CPU              Scale
    DB25 


        DB9
    Female          Male
     

      2 — Transmit — 3
      3 — Receive  — 2
      4 —
          | Loopback
      5 —
      7 —  Ground  — 1
    Switches

    Leave at default settings(all OFF)
    Levelling

    Lift off top platter and adjust legs until bubble is centered within circle.
    Calibration

    Software Interface

    Touchnet shells to SCALE.EXE which transmits a request out COM2 and waits up to five seconds for a valid response.  The status is returned through Branch and must be zero or an error has occured.  The scale groups all errors into a single byte added so many error numbers are possible but the common ones are listed below.  If the status is zero then dollar 3 will contain the weight in hundredths of a pound.

    Status    Cause


       


      0            Good transmission
      1            Scale in motion
      2            Weight greater than 30 lbs
      3            Invalid response from scale
      4            Weight less than zero
      9            No response from scale