Cabling
UDM COM port to UDM COM port(used with INTERLNK)
DSR 3 — 5 DTR
TXD 4 — 6 RXD
DTR 5 — 3 DSR
RXD 6 — 4 TXD
Note: Do NOT connect pins 1 or 8 as they contain voltages up to 30V.
I/O Device
AMC Mag Stripe Reader
RJ45 HR0025 DB9
Immage MSR
Black 3 RXD — 3 — 2
Green 5 TXD — 2 — 3
Orange 2 GRD — 7 — 5
Yellow 6 DSR — 6 — 8
5
8
Ardac Bill Acceptor
RJ45 DB25
Immage Ardac
Black 3 3
Green 5 2
Orange 2 7
Lantastic
UDM requires that AI-NDIS protocal manager be installed along with Lantastic as network card is not directly supported by Lantastic.
[color=red:30qn75pb][u:30qn75pb][b:30qn75pb]Download network files[/b:30qn75pb][/u:30qn75pb][/color:30qn75pb][/url:30qn75pb]
Config.Sys
Add these commands:
DEVICE=C:LANTASTIPROTMAN.DOS /I:C:LANTASTI
DEVICE=C:LANTASTISMC9000.DOS
Autoexec.Bat
Add this command:
AI-NDIS BIND_TO=SMC9000_NIF
Files Needed on Hard Drive
PROTMAN.EXE
PROTMAN.DOS
PROTOCOL.INI
SMC9000.DOS
REDIR
AI-NDIS
AILANBIO
NETBIND.COM
NET.EXE
MEMSET Command
The UDM video mode is programmable. It is therefore possible for it to lose its video setting. The result of this occurence is that the display in Touchnet will have strange flashing characters on some screens instead of the correct graphics character. The fix is to run:
MEMSET CLEAR
This utility resides in the UTIL directory.